Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Acta Pharmaceutica Sinica ; (12): 760-766, 2023.
Article in Chinese | WPRIM | ID: wpr-965633

ABSTRACT

The goal of this work was to explore the prospect of standardized application of an in-vitro bioactivity assay for recombinant human follicle-stimulating hormone based on a reporter gene. The relative accuracy, intermediate precision, linearity and applicable range of the method were validated according to the General Rules of Chinese Pharmacopoeia 2020 edition Volume IV (9401). Three laboratories used this method to determine the in-vitro biological activities of six batches of drug product and three batches of drug substance manufactured by two different companies. The consistency of the potency determined by three laboratories, the intra-laboratory precision and inter-laboratory precision were analyzed. The method was optimized during the collaborative validation. The results of method validation meet the requirements of the General Rules of Chinese Pharmacopoeia 2020 edition Volume IV (9401). Aiming to resolve the problems found in the collaborative validation, the medium for cell seeding, the pre-diluted buffer solution of standard and sample, and the means of removing and discarding supernatant after stimulation were optimized. After optimization, there was no significant difference in the bioactivity among the different laboratories (P > 0.05), indicating statistical equivalency. Intra-laboratory and inter-laboratory precision were good and the geometric coefficient of variation (GCV%) were both less than 15%. In conclusion, the reporter gene assay has good intra-laboratory repeatability and inter-laboratory reproducibility and is suitable for analyzing recombinant human follicle-stimulating hormone drug product and drug substance by different manufacturers. It is expected to be used as a standardized method for the determination of the in-vitro bioactivity of such products.

2.
Acta Pharmaceutica Sinica ; (12): 1010-1014, 2020.
Article in Chinese | WPRIM | ID: wpr-821679

ABSTRACT

A collaborative inter-laboratory validation was carried out using a reporter gene assay to measure the bioactivity of anti-PD-1 monoclonal antibody, in order to study the applicability and transferability of the method. In this study, two collaborative schemes were designed to measure the precision, linearity and accuracy of the method. The results showed that the 95% confidence interval (CI) of the intra-assay precision was (1.72-16.89) %, inter-assay precision was (2.63-17.67) %, inter-laboratory precision was (9.00-14.26) %, all linear correlation coefficients were greater than 0.99, and the 95% CI for the accuracy at different potency levels was (91.83-104.40) % at 50%, (90.40-101.40) % at 75%, (94.71-105.60) % at 100%, (94.00-102.00) % at 125%, and (96.73-104.30) % at 150%. The collaborative validation results proved that the reporter gene assay for the bioactivity determination of anti-PD-1 monoclonal antibody has good precision, linearity and accuracy, and could be applied to the release and stability analysis of anti-PD-1 monoclonal antibodies in different laboratories.

SELECTION OF CITATIONS
SEARCH DETAIL